Technology and specifications
All technical data for the WaterAccu in one place: exactly what the Nymo does, what it connects to, and its limitations. If you've come from How it works, you've had the explanation and this is the deep dive.
01
What do you have at home now?
The Nymo works alongside almost any way you currently make hot water. Choose what you have at home, and you'll see what changes with the WaterAccu.
1Combi boiler
the boiler provides hot water and heats the house, as in nine out of ten homes
The electric water heater is installed before the combi boiler. The domestic hot water is first pre-heated with your own solar power; the boiler only tops up what is needed.
Now The combi boiler heats the domestic hot water and the central heating.

With WaterAccu Domestic hot water first goes through the electric water heater, then through the combi boiler.

Components
The Nymo (main unit and sensor*), plus an electric water heater without electronic or smart functions.
How it works
Unused solar power goes via the Nymo to the electric water heater and heats the domestic hot water.
Post-heating on gas
The pre-heated domestic hot water flows through the combi boiler. If the water only reaches 45 °C on a cloudy day, the boiler brings it up to 60 °C.
Top-up heating on electricity
The Nymo can be programmed so that the water heater, for example in winter, tops up at 7 am using grid power.
Installation advice
An NZ connection kit may be needed to make the combi boiler suitable for hot-fill. Additionally, an optional temperature sensor can be added if the combi boiler fires up unnecessarily based on flow instead of temperature.
* Or P1 measurement via Homey.
2Hybrid heat pump
the heat pump heats the house, the boiler provides the hot water
With a hybrid heat pump, you place the Nymo alongside it for the domestic hot water. The heat pump continues to handle the central heating unchanged and the boiler remains the backup for both.
Now The hybrid heat pump handles the central heating, with the boiler as backup. The domestic hot water still runs on gas.

With WaterAccu The electric water heater is placed before the boiler, just like in setup 1.

Components
The Nymo (main unit and sensor*), plus an electric water heater without electronic or smart functions.
How it works
Unused solar power goes via the Nymo to the electric water heater for the domestic hot water. Nothing changes for the heat pump.
Post- and top-up heating
Same as setup 1: on gas via the combi boiler, or on grid power at a programmed time.
Please note
A heat pump boiler, where the heat pump is built into the water heater, cannot be used with the Nymo.
* Or P1 measurement via Homey.
3Fully electric heat pump
the heat pump does everything, with a buffer tank and a domestic hot water tank
No extra water heater is added. The Nymo feeds a separate electric immersion element in the existing domestic hot water tank, taking over the final, most expensive part of the heating.
Now One heat pump heats the central heating buffer tank and the domestic hot water tank.

With WaterAccu Elements in the tanks run on solar power via the Nymo.

Components
The Nymo (main unit and sensor*) and a separate electric immersion element, preferably 3 kW, in the domestic hot water tank. Optional second element in the central heating buffer tank.
How it works
A heat pump becomes less efficient the higher it has to heat. Often it brings the domestic hot water to 40 °C and then it goes electrically to 60 °C. The Nymo takes over exactly that part.
Two outputs
The element in the domestic hot water tank is on Nymo output 1 and takes priority. An element in the buffer tank on output 2 receives any solar power that is left over.
Post- and top-up heating
The remaining heat demand stays with the heat pump, which consequently uses less grid power in the evenings and at night.
Please note
In summer, output 2 can be switched off to prevent unnecessary heating during months when no heating is needed but there is a solar surplus.
* Or P1 measurement via Homey.
4Combi boiler with extra central heating tank
like 1, but the heating also benefits
An extension of setup 1. The domestic hot water heater remains separate from the central heating. A separate tank or small water heater in the central heating return captures any solar power that is left over.
Now The same starting situation as setup 1.

With WaterAccu The electric water heater takes priority; the rest goes to the element in the central heating tank.

Components
The Nymo (main unit and sensor*), an electric water heater for the domestic hot water, and a separate central heating tank or water heater with an electric element in the central heating return pipe.
How it works
The domestic hot water heater is on Nymo output 1 and takes priority. Once that is up to temperature, the remaining solar power goes via output 2 to the element in the central heating tank, which pre-heats the return water from the heating.
Post- and top-up heating
The combi boiler tops up whatever else is needed for both the domestic hot water and the heating. Top-up heating on electricity can be done at a programmed time.
Please note
How much pre-heating the central heating water saves depends heavily on the household and the timing; Solyx does not provide an estimate for this.
Note for summer
In summer, output 2 can be switched off to prevent unnecessary heating during months when no heating is needed but there is a solar surplus.
* Or P1 measurement via Homey.
5District heating
hot water and heating come from district heating
For most of the year, domestic hot water comes from your own solar power instead of often pricey district heating. A three-way valve automatically switches back when necessary.
Now District heating provides hot water for heating and domestic use.

With WaterAccu The three-way valve chooses between the electric water heater and the hot water supply from the district heating.

Components
The Nymo (main unit and sensor*), an electric water heater without electronic or smart functions, and a three-way valve with a temperature sensor.
How it works
Unused solar power goes via the Nymo to the electric water heater, which provides the domestic hot water.
Post-heating
A temperature sensor measures the water from the electric water heater. If it drops below 40 °C, the three-way valve opens the supply from the district heating. Once the water heater can provide water above 40 °C again, the valve switches back.
Central heating
Remains unchanged on the district heating.
Please note
The exact installation must be reviewed with an installer, as district heating systems can vary.
* Or P1 measurement via Homey.
Prefer everything together? Download the setups with diagrams (PDF) (opens in a new tab)
02
What it connects to
The Nymo works independently of the brand of your solar panels, your inverter, your central heating boiler, and your electric water heater. What does matter is listed below.
Smart meter
A P1 port (the small socket for a plug on your meter). With DSMR 5.0, i.e. meters from 2015 onwards, the sensor works without issue. With DSMR 4.2 it also works, but the sensor needs a separate power supply via USB-C. Kamstrup meters and meters from 2014 or older do not work.
Electric water heater
Single-phase, maximum 3,000 W, without display, timer, or other electronics, and with a mechanical thermostat (a dial for the temperature). Heat pump boilers and smart water heaters are not supported.
Combi boiler optional
Only relevant if you want to post-heat via the boiler. It must then be less than fifteen years old and have the NZ quality mark, which can be found on the gas inspection sticker. Without post-heating, this requirement does not apply.
Panels and inverter
Brand and type do not matter, and nothing needs to change on the inverter. Nothing extra is added to the roof either: the Nymo uses the panels that are already there.
Does it work with what you already have?
Single-phase or three-phase
both
Both. The Nymo works with single-phase and three-phase home connections and inverters. The sensor adds up the feed back to the grid across all phases into one value, and the main unit regulates based on that. The electric water heater it controls is single-phase, which applies to almost all household water heaters up to 200 litres.
The P1 port is already occupied
can be solved with a splitter
In that case, a P1 splitter can be used, available in our webshop for €16, which allows two devices to work on the same port. This is only possible with DSMR 5.0 or higher. Please note that not every smart meter provides enough power to feed a splitter and two devices; in that case, an active splitter with its own power supply is required.
Insufficient range between sensor and main unit
rare, and can be solved
The range is 1 to 30 metres indoors, at 433.92 MHz. This is more than enough for almost any home, even if the consumer unit and the water heater are on different floors. If the signal is still too weak, there are two solutions: a longer P1 cable, so the sensor hangs closer to the main unit, or a different antenna. The latter usually helps.
A home battery
is possible, with the right threshold values
Can be used alongside. Both systems look at the P1 port. What you set depends on what kind of battery you have.
A battery for own use, which does not feed anything back to the grid. In that case, you only set who gets priority, and it is usually most beneficial to give that to the battery. The Nymo starts by default at 100 W surplus, threshold value 1. If your battery starts earlier, it will work out fine automatically. If it starts later, then you increase threshold value 1 on the Nymo. If the Nymo still charges from the battery, set threshold value 2 to 50 W. Homey is not required for this.
A battery that also feeds back, for example to trade on the imbalance market. The Nymo sees no difference between power your panels feed back and power the battery feeds back, and would put the latter into the electric water heater. The simplest solution is a timer or smart plug before the Nymo, which turns it off outside solar hours. Outside those hours, the battery is free to feed back to the grid. With Homey or Home Assistant you can let both work together automatically. Exactly how depends on the systems you have.
A charging station
no conflict
No interference. The Nymo starts as low as 100 watts surplus, while a charging station usually needs about 1,300 before it kicks in. As a result, the Nymo automatically takes the small surpluses and the charging station the large ones.
A dynamic energy contract
beneficial, and can be linked via Homey
Works perfectly: lots of sun means low prices, so using your own surplus is still beneficial. If you want to control the water heater directly based on the daily price, you can do so via the link with Homey.
A heat pump or district heating? Check What do you have at home now?
What must definitely not be connected
The Nymo emits a direct current signal. Only heating elements and other ohmic resistances may be connected to it. Household appliances run on alternating current and will be damaged if you connect them. Home batteries and charging stations also cannot be connected.
03
How the Nymo regulates
The Nymo is not a switch but a power regulator. It doesn't just switch on or off, but provides exactly the power you have left over at that moment.
Stepless between 100 and 3,000 watts
The sensor reads the P1 port of your smart meter and sees what is going into the grid at that moment. That figure goes wirelessly to the main unit, which hangs between the socket and the water heater and feeds the heating element with exactly that power. Solar generation and consumption fluctuate throughout the day due to clouds and appliances switching on and off, and the Nymo follows that line from moment to moment.
Below 100 watts, it switches off. Above 3,000 watts, it caps at the maximum power of the element.
What that means in practice
- 80 W surplus
- Nothing. Below one hundred watts, the Nymo stays off.
- 1,850 W surplus
- 1,850 watts to the electric water heater. Nothing goes to the grid and nothing is bought in.
- 3,400 W surplus
- 3,000 watts to the electric water heater, or the maximum of the element if that is lower. The rest still goes back to the grid.
Why a smart plug cannot do this. A switch can only be on or off. If you generate 1,600 watts while your water heater requires 2,400, you still pull those missing 800 watts from the grid. Because the Nymo regulates the power, it more than doubles the annual savings compared to a smart switch.
04
Specifications
The main unit and the sensor, including the standards they meet.
Nymo main unit
- Voltage
- 220 to 240 V AC, single-phase electric water heater or heating element
- Maximum permissible load
- 3 kW electric heating elements, 13 A resistance
- Control range
- 100 to 3,000 W, stepless
- Outputs
- Two, output 1 and output 2, both within 3 m
- Weight
- 2.2 kg
- Dimensions
- 166 × 243 × 91 mm
Sensor
- Smart meter
- P1 port, DSMR 5.0 (meters from 2015) or DSMR 4.2 with own power supply
- Radio range
- 1 to 30 m indoors
- Radio frequency
- 433.92 MHz
- Dimensions
- 67 × 67 × 30 mm, excluding antenna
Applicable standards Main unit: EN 300 220-2, EN 301 489-1, EN 301 489-3, EN 55014-1, EN 55014-2, EN 61000-3. Sensor: EN 300 220-2, EN 301 489-3.

What is delivered
The box contains the main unit, the sensor for your consumer unit, the P1 cable, and the mounting material. The electric water heater is a separate appliance and is only included if you order it as well.
Connecting it takes about twenty minutes. The main unit hangs next to the water heater, the sensor clicks into the P1 port of the smart meter, and the two find each other wirelessly. So no cables need to be run through the house and no specialist knowledge is required.
05
The water heater and storage
The water heater is the battery. How much you can store therefore depends on the size you choose, and you choose that based on your household.
Size, household, and storage
- 100 L1 to 2 people, approximately 7 kWh storage
- 150 L3 to 4 people, approximately 10 kWh
- 200 Lfrom 5 people, approximately 14 kWh
For comparison: an average home battery stores 4 to 6 kWh. Even the smallest water heater we supply exceeds that.
Two water heaters on one Nymo
Possible. The main unit has two outputs. Output 1 takes priority, and as soon as it is up to temperature, the Nymo switches to the second one. Note two things: Output 2 does not have legionella protection, and both water heaters must be within 3 metres of the Nymo.
What the water heater must not have
No display, no timer, no electronics. A mechanical thermostat is a requirement: water heaters with an electronic thermostat do not work with the Nymo. The heating element must be single-phase, which is standard for all household water heaters up to 200 litres. Heat pump boilers and smart water heaters are excluded.
What we recommend
The Tesy Anti-Limescale Reversible: well-insulated and therefore efficient, maintenance once every five years instead of every two, an anti-limescale element, five-year warranty, and easy to install yourself. Also compatible are the Bosch Tronic, the Stiebel Eltron Classic, and the Itho Daalderop Mono.
That Tesy is reversible: you can hang it vertically or horizontally on the wall, or place it horizontally on the floor. If there is no space vertically, for example under a sloping roof, this is the solution. For the floor, floor brackets are included. If you want 200 litres, there is the OSO Saga made of stainless steel, which stands on the floor and requires no maintenance.
06
The programmes
Over the whole year, about two-thirds of your hot water comes from the sun. In summer, it's often all of it; in winter, less. For the rest, there are three programmes.
Legionella protection
automatic, after seven days
Automatic, and you don't need to set anything for it. The Nymo keeps track of when the water heater last reached its maximum temperature. If seven days pass without that happening, it heats the water heater all the way through anyway. Once that temperature is reached, the timer starts again, so no energy is wasted on an unnecessary cycle.
Please note: this applies to output 1. A second water heater on the same Nymo does not have this protection.
Scheduled top-up heating
with grid power, at your chosen time
In the Nymo's main menu, you can set the water heater to top up at a fixed time using grid power, for example at seven o'clock in winter. This way, you have hot water even after a week of rain, and you choose the moment it happens.
This is also the route for those who want to get off gas entirely: without a central heating boiler, this programme takes over the post-heating.
Post-heating on gas
via your combi boiler
If you connect the output of the electric water heater to your combi boiler, it will top up what the sun didn't manage. On a cloudy day, for example, the water might reach 45 degrees in the water heater, after which the boiler brings it up to 60.
The requirement for the boiler applies here: less than fifteen years old and with the NZ quality mark.
07
Homey and the Solar iBoost
Two exceptions to the standard story: the version for those who have Homey, and the product that the Nymo succeeded.
Nymo x Homey
our sensor is then redundant
If you have Homey at home, it already measures your power and our sensor is unnecessary. The WaterAccu will then appear in the Homey app, alongside the rest of your devices.
What you need for it: a Homey Pro (2023 or 2026) or a Homey Bridge, plus a suitable P1 dongle. That dongle reads your smart meter and sends the data to Homey, which in turn talks to the Nymo via 433 MHz. Older generations of the Homey Pro and the cloud version do not work. The Nymo requires software version 3.01 or higher.
What it adds: letting the Nymo respond to dynamic energy prices, letting it work together automatically with a charging station or a home battery that feeds back, and remote control: on, off, or heating at a scheduled time.
To the Nymo x Homey manual → (opens in a new tab)
Already have a Nymo? Then it probably needs a software upgrade. Email info@solyxenergy.nl, and you will receive a quote for that upgrade.
The difference with the Solar iBoost
the Nymo is the successor
The Solar iBoost was our original product and only works with single-phase systems. The Nymo is the successor: it works with both single-phase and three-phase systems, and it connects to your smart meter, making installation a lot easier.
The Solar iBoost is no longer for sale. If you still have one, the manual is available on the site.
08
Compared to a home battery
A home battery stores your power to be power again later. The WaterAccu turns it into hot water, thereby replacing your gas. Two different things, so here is also where the home battery wins.
| WaterAccu | Home battery | |
|---|---|---|
| Storage capacity | 10 kWh · 150L electric water heater | 10 kWh |
| Store as | Hot water (thermal) | Electricity |
| Purchase price | €1,189 (Nymo + water heater) | €4,000 to €10,000 |
| Payback period | approx. 3.5 years | 7 to 12 years |
| Usable for lighting, TV, etc. | No | Yes |
| Gas savings | Yes | No |
| Installation | The Nymo: 20 min, DIY | Professional required |
| Dynamic tariff integration | Yes, via Homey | Full |
- The storage of the WaterAccu depends on the water heater size: approximately 7 kWh for 100 litres, 10 for 150, and 14 for 200.
- The purchase price applies to the Nymo with a 150-litre water heater, enough for a household of three, excluding installation. If you already have a suitable water heater, only the Nymo is needed, for €649.
- The payback period of approximately 3.5 years applies to the Nymo with a 150-litre water heater, for three people. If you have the whole thing installed, it is approximately 5 years. For the Nymo alone, on an existing water heater, it is approximately two years.
- DIY connection applies to the Nymo: you click it between your consumer unit and your water heater in about twenty minutes. If you add a water heater, you can hang it yourself or have it done. Here's how that works, step by step →
- A home battery provides power for everything in the house and is more versatile in that regard. The WaterAccu does one thing, replaces gas with it, and costs a fraction of the price.
09
Warranty and documents
What you can rely on
- Warranty
- Two years on the Nymo and five years on the Tesy. On the OSO, five years on the tank and one year on the heating element. On other electric water heaters, the manufacturer's warranty applies.
- Cooling-off period
- Fourteen days, even if there is nothing wrong: return unused, money back.
- Delivery
- Delivered within three working days, free shipping.
- Support
- Dutch, and you'll speak to someone who knows the device. 033 208 7460, Monday to Thursday between 9:00‑14:00.
The documents
- Installation manual PDF Mounting, connection and commissioning, with photos of every connection.
- User manual PDF The settings, the programmes and what the display tells you.
- All manuals Including Nymo x Homey, the Solar iBoost and the English, German and French versions.
- For installers Purchasing, delivery and warranty for installers, webshops and wholesalers.
Is your question not listed?
Feel free to ask. You'll get an answer within one working day, from someone who knows the Nymo inside out.